Power requirements, Power requirements 2-4 – IBM Print System QMS 4032 User Manual

Page 20

Advertising
background image

/  

0" 

    



   



Your printer requires a properly grounded AC outlet with a rated line voltage of 100
V, 120 V, or 220-240 V.



The line voltage must remain within ±10 percent of the rated voltage for proper
operation of the printer.



The amperage capacity of the electrical outlet must be at least 1.2 times that used
by the printer.



The maximum electrical current required during operation is 9.5 amps for a 100 V
system, 9.5 amps for a 120 V system, and 5.2 amps for a 220-240 V system.



Noise-generating equipment should not be connected to the same electrical outlet
as the printer.



The recommended frequency is 50-60 Hz ±3 Hz for a 100 V system, 50-60 Hz ±3
Hz for a 120 V system, and 50-60 Hz ±3 Hz for a 220-240 V system.

%  & 

The QMS 3260/4032 Print System is compliant with
US Environmental Protection Agency (EPA) Energy
Star regulations (printer without advanced paper han-
dling options.) After a specified period of inactivity, the
printer changes to a low-power state (the engine
remains on, but the fuser turns off). When a print job
is received, the printer returns to normal power within
90 seconds.

Advertising
This manual is related to the following products: