Chapter 53. Rack cabinets and options

465


Notes:
1.

Optional rack power cords: P/N 94G6667 - 14ft NEMA 5-15P; P/N 94G7448 - 14ft IEC 320-C14.

2.

1U = 1.75in (44.45mm).

3.

Weight equals maximum configuration, except for the 4559 Tape Enclosures where it is the weight
without tape drives.

4.

Power inlets are IEC 320-C14, except for the BladeCenter with 2000W power supplies and the x365,
which have IEC 320-C20 inlets.

5.

Rack installation requires appropriate tower-to-rack conversion kit.

6.

Additional power cords are not required. This power supply option shares use of line cords provided
with the base system. Should be ordered in pairs to maintain redundancy.

7.

If installed in older IBM racks, the server should not be installed behind a glass door that blocks air flow.
Remove the glass door or replace with an optional perforated door. To order a rack extension kit for
withdrawn IBM racks, visit the Options Continuation Program Website at www.pc.ibm.com/ww/ocp.

8.

Internal power supply logic limits low voltage (100-127 VAC) to 550w per power supply. Thus,
configurations requiring more power are not redundant for low voltage installations, e.g., configurations
with more than two processors.

Storage Units:

EXP400

17331RU

3

22

85

352/440

2/2

2

2

DS300

1701xxx

3

23

90

391/558

1/2

1

DS400

1700xxx

3

23

90

391/558

2/2

2

DS4100

1724100

3

22

99

273/390

2/2

2

DS4300

172260U

3

24

102

275/390

2/2

2

2

DS4400

17421RU

4

24

85

140/200

2/2

2

2

DS4500

174290U

4

24

85

140/200

2/2

2

2

DS4000 EXP100

171010U

3

23.5

89

245/350

2/2

2

2

DS4000 EXP710

1740710

3

23

101

273/390

2/2

2

2

FC Switch 8-port

3534F08

1

10

12

85

1/1

FC Switch 16-port

2005H16

1

12

12

200

2/2

Tape Components:

NetBAY 1U Tape
Enclosure

45591UX

1

20

16

3

100

1/1

1

NetBAY 4U Tape
Enclosure

45594UX

4

18

25

3

300

1/1

1

1

SDLT/LTO Modular
Tape Library

4560SLX

5

31

70

300

1/1

1

IBM Rack-Mounted Units

Standard Power Cords

1

Descripti

o

n

Mac

hine

Type / Mo

del

Si

ze (U)

2

Depth (in)

Ap

prox W

e

ight

3

(l

bs)

3

Power (

Watts)

Typical/Max

N

u

mber of P/S &

Line Cords

(Basic/Max)

4

6ft NEMA 5-15P

P/N 6952301

9ft NEMA 5-15P

P/N

695

2300

9ft NEMA 6-15P

P/N

183

8574

9ft IEC 320-C13/C14

P/N 36L888

6

8ft IEC 320-C19/C20

P/N

00N

7701

Y-cable 2xC13/C1

4

P/N 25R2567

Advertising