Chapter 2. Installing Options

9

Note:

The illustrations in this document might differ slightly from your
hardware.

5. Remove the expansion-slot cover.

6. Refer to the documentation that comes with your adapter for any cabling

instructions.

Attention:

You should route adapter cables before you install the adapter.

Note:

When installing a ServeRAID adapter, remove the cable from the SCSI
connector (J4) on the system board and attach it to the ServeRAID
adapter.

7. Set any jumpers or switches as described by the adapter manufacturer.

8. Install the adapter:

Note:

When installing an adapter into slot 2, skip steps a and d.

a. Open the adapter retention latch by pushing the blue tab to release it. Then,

push the latch up to the full open position.

b. Carefully grasp the adapter by its top edge or upper corners, and align it with

the connector on the PCI riser card.

c. Press the adapter firmly into the riser-card connector.

Attention:

When you install an adapter, be sure the adapter is correctly

seated in the riser-card connector before you turn on the server. Improperly
seated adapters might cause damage to the system board, the riser card, or
the adapter.

Retention
latch

Tab

Adapter
card

Expansion
slot cover

Expansion
slot clip

Expansion
slot