IBM eserver xSeries 330 User Manual

Page 28

Advertising
background image

16

IBM® xSeries 330: Installation Guide

Attention:

When you handle electrostatic discharge (ESD) sensitive devices, take

precautions to avoid damage from static electricity. For details on handling these
devices, refer to “Handling static sensitive devices” on page 4.

1. Review the safety precautions beginning on page v.

2. Turn off the server and peripheral devices.

3. Remove all external cables from the server; then, remove the server from the rack

and remove the cover. For more information on removing the cover, refer to the
User’s Reference on the IBM xSeries Documentation CD.

4. Remove the plastic shield from the server.

5. Lift up the microprocessor release lever and remove the terminator card from the

microprocessor connector.

6. Install the microprocessor in the microprocessor connector.

Attention:

To avoid bending the pins, do not use excessive force.

7. Push the release lever down to lock the microprocessor into place.

8. Install the heat sink onto the microprocessor.

9. Replace the clear shield.

Notes:

a. The clear shield must be installed to maintain proper air flow and cooling

inside the server.

b. If you have other options to install, install them now.

10. Replace the cover on the server; then, reinstall the server in the rack and connect

all external cables. For more information on replacing the cover, refer to the User’s
Reference
on the IBM xSeries Documentation CD.

11. Turn on the server and run the Configuration/Setup Utility program.

Clip

Heatsink

Microprocessor

Terminator card

Heatsink release

lever

Slot

Top view of

heatsink

Advertising