IBM eserver xSeries 330 User Manual

Page 32

Advertising
background image

20

IBM® xSeries 330: Installation Guide

Complete the following steps to connect the servers:

1. Gather several of the C2T chaining cables.

Note:

Your server comes with a short C2T chaining cable that can span
approximately 3 U’s, if needed. A longer C2T cable is available in the
C2T cable kit.

2. Connect the servers together:

a. Connect one end of the C2T chaining cable to the Console (Out) port of the

top server.

b. Connect the opposite end of the C2T chaining cable to the Console (In) port of

the server below it. Refer to the following illustration for additional
information.

c. Repeat these steps until all of the servers are connected together.

d. Connect the C2T device break out cable to the server 1 Console (Out) port.

Note:

Server 1 (usually the server at the bottom of the rack) is the server to
which you connect the device break out cable.

3. Turn the servers on and check the operation of the monitor, pointing device, and

keyboard with each server. (See “Testing the C2T chain” on page 21 for testing
instructions.)

Note:

Write-on adhesive labels have been provided so that you can label the server
position in the rack.

In

In

Out

Out

Out

Out

In

In

Mouse

Keyboard

Video

4

3

2

1