Ram parity error – checking for segment, Slot not empty, System halted, (ctrl-alt-del) to reboot – Intel ECB-870 User Manual

Page 108: Floppy disk(s) fail (80), Unable to reset floppy subsystem, Floppy disk(s) fail (40), Floppy type dismatch, Hard disk(s) fail (80), Hdd reset failed, Hard disk(s) fail (40)

Advertising
background image

User’s Manual

96 ECB-870 User’s Manual

RAM Parity Error – Checking For Segment...

Indicates a parity error in Random Access Memory.

Should Be Empty But EISA Board Found
Please Run EISA Configuration Utility

A valid board ID was found in a slot that was configured as having no board ID.

NOTE; When this error appears, the system will boot in ISA mode, which allows you to run the EISA
Configuration Utility.

Should Have EISA Board But Not Found
Please Run EISA Configuration Utility

The board installed is not responding to the ID request, or no board ID has been found in
the indicated slot.

NOTE: When this error appears, the system will boot in ISA mode, which allows you to run the EISA
Configuration Utility.

Slot Not Empty

Indicates that a slot designated as empty by the EISA Configuration Utility actually
contains a board.

NOTE: When this error appears, the system will boot in ISA mode, which allows you to run the EISA
Configuration Utility.

System Halted, (CTRL-ALT-DEL) To Reboot...

Indicates the present boot attempt has been aborted and the system must be rebooted.
Press and hold down the CTRL and ALT keys and press DEL.

Wrong Board In Slot
Please Run EISA Configuration Utility

The board ID does not match the ID stored in the EISA non-volatile memory.

NOTE: When this error appears, the system will boot in ISA mode, which allows you to run the EISA
Configuration Utility.

Floppy Disk(s) Fail (80)

Unable To Reset Floppy Subsystem.

Floppy Disk(s) Fail (40)

Floppy Type Dismatch.

Hard Disk(s) Fail (80)

HDD Reset Failed

Hard Disk(s) Fail (40)

HDD Controller Diagnostics Failed.

Hard Disk(s) Fail (20)

HDD Initialization Error.

Advertising