Intel ECB-870 User Manual

Page 71

Advertising
background image

ECB-870

ECB-870 User’s Manual 59

4.5.5.9 Onboard FDC Controller

Select “Enabled” to activate the on-board FDC and “Disabled” to activate an add-on FDC.

The choice: Disable, Enable.

4.5.5.10 Onboard Serial Port 1 & 2

Select an address and corresponding interrupt for the first/second serial port. The default
value for the first serial port is “3F8/IRQ4” and the second serial port is “2F8/IRQ3”.

The choice: Disable, 3F8/IRQ4, 2F8/IRQ3, 3E8/IRQ4, 3F8/IRQ3, and Auto.

4.5.5.11 UART Mode Select

Select to activate the Infrared transfer function.

The choice: IrDA, ASKIR, Normal.

4.5.5.12 RxD , TxD Active


This choice: Hi, Lo; Lo, Hi; Lo, Lo; Hi, Hi.

4.5.5.13 IR Transmission Delay

If this option is enabled, transmission of data will be slower. This is recommended when
you encounter transmission problem with your device.

The choice: Disable, Enable.

4.5.5.14 UR2 Duplex Mode

Select to activate the Infrared transfer function. This default setting is “Half“.

The choice: Full, Half.

4.5.5.15 Use IR Pin

When you select to IrDA or ASKIR mode, you can define use (TX,RX ) pin.

The choice: RxD2, TxD2; IR-Rx2Tx2.

4.5.5.16 Onboard Parallel Port

Select address and interrupt for the Parallel port.

The choice: Disable, 378/IRQ7, 278/IRQ5, and 3CB/IRQ7.

4.5.5.17 Parallel Port Mode

Select an operating mode for the parallel port.

The choice: SPP, EPP, ECP, ECP+EPP, and Normal.