Getting alarm output time setting from vn-v686, Setting alarm output time for vn-v686, Getting alarm output status from vn-v686 – JVC VN-V686UAPI User Manual

Page 52: Changing alarm output of vn-v686

Advertising
background image

For Post Duration

/api/param?application.object.postrec&200 OK

Interpretation Change parameters for PrePost + ftp. These parameters are used when recftp is set as an alarm

action. Specify 30, 15, 10, 7.5, 6, 5, 3, 2, or 1 for frame rate. Maximum Pre/Post duration is 60 seconds. Setting zero

to Pre and Post duration is invalid.

Allowed users admin, operator

Getting Alarm Output Time Setting from VN-V686

Format

/api/param?peripheral.output_pin.pin(Number).duration

Example /api/param?peripheral.output_pin.pin(1).duration

Example of Response

peripheral.output_pin.pin(1).duration=500&200 OK

Interpretation Acquire the current alarm output duration in millisecond. Specify 1 or 2 to Number. When returned

value is 0, it means infinite output.

Allowed users admin, operator, user

Setting Alarm Output Time for VN-V686

Format

/api/param?peripheral.input_pin.pin(Number).duration=data

Example

/api/param?peripheral.input_pin.pin(1).duration=50

Example of response

peripheral.input_pin.pin(1).duration&200 OK

Interpretation Change the alarm output duration in millisecond. Specify 1 or 2 to Number. Specify 0, or 100 to

5000 for the duration. When 0 is set, output duration becomes infinite.

Allowed users admin, operator

Getting Alarm Output Status from VN-V686

Format

/api/param?peripheral.output_pin.pin(Number).status

Example of Response

peripheral.output_pin.pin(1).status=make&200 OK

Interpretation Acquire the current alarm output status. Specify 1 or 2 to Number. Either make or break will be

returned.

Allowed users admin, operator, user

Changing Alarm Output of VN-V686

Format

/api/param?peripheral.output_pin.pin(Number).status=data

Example

/api/param?peripheral.output_pin.pin(1).status=break

Example of Response

peripheral.output_pin.pin(1).status&200 OK

Interpretation Change the alarm output. Specify 1 or 2 to Number. Specify "make" or "break" to data.

When the alarm output time is zero, alarm output is changed as this API specifies. When the alarm output time is not

zero, alarm output is changed as this API specifies, then alarm output is changed again after the alarm output time.

52