Getting tilt limit from vn-v686, Setting tilt limit for vn-v686, Getting auto flip setting from vn-v686 – JVC VN-V686UAPI User Manual

Page 61

Advertising
background image

Getting Tilt Limit from VN-V686

Format

/api/param?camera.motion.tilt.limit.upper

Example of response

camera.motion.tilt.limit.upper=5&200 OK

Interpretation Acquire Tilt Limit in degrees.

Allowed users admin, operator, user

Setting Tilt Limit for VN-V686

Format

/api/param?camera.motion.tilt.limit.upper=data

Example to set horizontal

/api/param?camera.motion.tilt.limit.upper=5

Example of Response

camera.motion.tilt.limit.upper&202

Accepted(camera.status=save)

Interpretation Set Tilt Limit. Specify from 0 to 15. 5 is horizontal. The change is saved by the API,

camera.status=save. If the change is not saved, the setting is restored by reboot.

Allowed users admin, operator

Getting Speed of Going to Preset Position from VN-V686

Format

/api/param?camera.motion.position.speed

Example of response

camera.motion.position.speed=100&200 OK

Interpretation Acquire speed of going to preset position. Value from 0 to 100 is returned. 100 is fastest. The speed

is 4 steps internally. The speed is applied also to preset position of auto patrol.

Allowed users admin, operator, user

Setting Speed of Going to Preset Position for VN-V686

Format

/api/param?camera.motion.position.speed=data

Example to set horizontal

/api/param?camera.motion.position.speed=100

Example of Response

camera.motion.position.speed&202

Accepted(camera.status=save)

Interpretation Set speed of going to preset position. Specify from 0 to 100. 5 is horizontal. 100 is fastest. The

speed is 4 steps internally. The speed is applied also to preset position of auto patrol. The change is saved by the API,

camera.status=save. If the change is not saved, the setting is restored by reboot.

Allowed users admin, operator

Getting Auto Flip Setting from VN-V686

Format

/api/param?camera.motion.tilt.auto_flip

Example of response

camera.motion.tilt.auto_flip=full_digital&200 OK

Interpretation Acquire setting of auto flip. off, full_digital, half, full or full_reverse is returned.

61