Juniper Networks J-Series User Manual

Page 300

Advertising
background image

Table 141: Configuring Basic RPM Probes (continued)

CLI Configuration Editor

J-Web Configuration Editor

Task

1.

From the

[edit]

hierarchy level, enter

edit services rpm probe customerA

2.

Enter

set test icmp-test probe-frequency 15

3.

Enter

set test icmp-test probe-type

icmp-ping-timestamp

4.

Enter

set test icmp-test

hardware-timestamp

5.

Enter

set test icmp-test target address

192.178.16.5

1.

On the Rpm page, select
customerA.

2.

In the Test box, click Add new
entry

3.

In the Name box, type

icmp-test

.

4.

In the Test interval box, type

15

.

5.

In the Probe type box, select
icmp-ping-timestamp.

6.

Select the Hardware timestamp
check box.

7.

In the Target box, select the Yes
check box, and click Configure.

8.

In the Target type box, select
Address.

9.

In the Address box, type

192.178.16.5

.

10.

Click OK.

Configure the RPM test

icmp-test

for the

RPM owner

customerA

.

The sample RPM test is an ICMP probe
with a test interval (probe frequency) of
15 seconds, a probe type of

icmp-ping-timestamp

, a probe timestamp,

and a target address of

192.178.16.5

.

1.

Enter

set probe customerA test icmp-test

thresholds ingress-time 3000

2.

Enter

set probe customerA test icmp-test

traps ingress-time-exceeded

1.

On the Probe page, select
icmp-test.

2.

In the Thresholds box, select the
Yes check box, and click
Configure.

3.

In the Ingress time box, type

3000

.

4.

Click OK.

5.

In the Traps box, click Add new
entry
.

6.

In the Value box, select
ingress-time-exceeded.

7.

Click OK.

Configure RPM thresholds and
corresponding SNMP traps to catch
ingress (inbound) times greater than
3000 microseconds.

278

Configuring RPM with a Configuration Editor

J-series™ Services Router Administration Guide

Advertising