Appendix – JBL SYNTHESIS SDP-40HD User Manual

Page 163

Advertising
background image

SDP-40HD

Appendix

A-3

Specifications are subject to change without notice.

Output Level

• 200mVrms typical, 4Vrms maximum (RCA connectors)
• 400mVrms typical, 8Vrms maximum (XLR connectors,

Zone 2 only)

• Maximum value with full-scale input signal and volume at

0dB

Output Impedance

• 100

Ω

in parallel with 150pF (RCA connectors)

• 50

Ω

in parallel with 150pF (XLR connectors, Zone 2 only)

Video Input & Output Connectors

Video Inputs

• 2 composite (RCA), 3 S-video, and 4 component video (3

RCA and 1 BNC))

Video Outputs

• 4 composite (RCA, 2 main and 2 Record Zone), 2 S-video

(2 monitor and 2 Record Zone), and 1 component (BNC)

Composite & S-video Performance

Compatibility

• NTSC, PAL, and SECAM

Switching

• Active

Output Level

• 1.0V peak-to-peak

Impedance

• 75Ω

Input Return Loss

• >40dB

Differential Gain

• <0.3%

Differential Phase

• <0.3°

Bandwidth

• >25MHz

K Factor

• <0.3%

Gain

• ±0.15dB

Signal-to-Noise Ratio • >70dB

Frequency Response

• 10Hz to 8MHz + 0.2dB/-0.3dB

Component Video Performance

Compatibility

• 3-channel (Y, Pr, Pb), format-independent

Zone 2 & Record Zone Audio Performance

Switching

• Passive

Impedance

• 75Ω

Insertion Loss

• <3dB

Bandwidth

• >250MHz

Microphone Input Connectors

Inputs

• 4 3.5 miniature phone jacks

Input Sensitivity

• 10mVrms (400mV maximum input level)

Input Impedance

• 20kΩ (accepts balanced or unbalanced input signals)

Other

Trigger Outputs

• 1 power on/off and 2 programmable connectors on

detachable screw terminals (+12 VDC, 0.5 amps each)

RS-232 Serial Input/
Output

• 2 9-pin D-sub connectors

Power Requirements

• 90-250 VAC, 50-60Hz, 120W (universal line input),

detachable power cord

SDP-40HD
Dimensions &
Weight

• Height (with feet): 6.63 inches (169mm)
• Width: 17.3 inches (440mm)
• Depth: 14.85 inches (377mm)
• Weight: 45lbs (20.5kg)

Rack Mounting

• Optional brackets are available for installation in a

standard 19" equipment rack (4 rack units required)

Environment

• Operating Temperature: 0° to 35°C (32° to 95°F)
• Storage Temperature: -30° to 75°C (-22° to 167°F)
• Relative Humidity: 95% maximum without condensation

Remote Control

• Hand-held, backlit infrared remote control unit
• Requires 2 AA batteries (Alkaline batteries recommended)

Component Video Performance