John Deere HR-BG5202-NG User Manual

Page 11

Advertising
background image

Operator’s Manual



Preparation

VeNTuRI TuBeS

CauTION: KeeP VeNTuRI TuBeS CleaN. BlOCKaGeS

CauSed By SPIdeRS, INSeCTS aNd NeSTS CaN

CauSe a flaSHBaCK fIRe. (fIG. 4)

Although the grill might still light, the backed up gas might also ignite

and cause a fire around the venturi tubes at the control panel or side

burner.

WaRNING: If a flaSHBaCK fIRe OCCuRS, TuRN Off GaS

aT THe SOuRCe IMMedIaTely.

Inspect and clean the venturi tubes (main burner, side burner, rear

burner) if any of the following symptoms occur:
. You smell gas.
. Your grill does not reach temperature.
. Your grill heats unevenly.
4. The burners make popping noises.

INSPEcTING & clEANING VENTuRI TuBES:
. Turn off gas at the source.

i.e. the gas cylinder or supply line for natural gas.

. When grill is cool, remove burner fasteners from bottom, lift the

burner from the grill housing.

. Clean the venturi tubes with a pipe cleaner or venturi cleaning tool

(PN 67-0144). (Fig. 5)

4. Lower the burner into position in the grill housing, making sure that

the venturi tubes are correctly aligned and fitted on the orifices.

(Fig. 6)

5. Secure burner with burner fasteners.

Fig. 4

Fig. 5

Fig. 6

Venturi Tube

Spider Web

Tube Burner

Advertising