Troubleshooting – John Deere HR-BG5202-NG User Manual

Page 19

Advertising
background image

Operator’s Manual

9

Symptom

Problem

Solution

Smell Gas.

Shut-off Natural Gas Supply

at once. dO NOT use the

appliance until leak is sealed.

leak detected at regulator or

Regulator fitting loose.

Tighten fitting and “leak Test”.

other connections.

Gas leak in hose/regulator or control

See authorized service center.

valves.

Flame flashback beneath control panel. Venturi blocked.

Remove burner, clean ventrui.

See “Venturi Tube”.

Burner will not light.

Out of Natural Gas.

Refill.

Ignitor wire(s) not connected.

Connect both main burner and

side burner electrode wires.

Ignitor electrode misaligned on burner. Realign electrodes.

Ignitor malfunction.

Use “Manual Lighting” procedures.

Burner valve left open while gas

Close burner and gas valves.

valve was opened causing excess

Open gas valve slowly, then

flow device to activate.

open burner valve to light.

A leak in the system causing the

Leak test connections to

excess flow device to activate.

determine loose fitting. Tighten

fitting. leak test system.

Venturi blocked.

Remove burner, clean venturi See

“Venturi Tubes”.

Venturi not aligned with valve orifice.

Realign venturi to orifice. See

“Venturi Tubes”.

Orifice blocked.

Remove burner, clean orifice with

a pin or fine wire. Do not attempt

to drill orifice.

Hose is twisted.

Straighten hose. Keep away from

bottom casting.

Decreasing heat, “popping sound”.

Out of Natural Gas.

Refill.

Venturi blocked.

Remove burner, clean venturi.

See “Venturi Tubes”.

Hot spots on cooking surface.

Venturi blocked.

Remove burner, clean venturi.

See “Venturi Tubes”

Troubleshooting