Operating the Generator

Operator’s Manual

27

OPERATION

Electric Start

CAUTION: CHECK THE OIL LEVEL BEFORE EACH

OPERATION AS OUTLINED ON PAGE 21.

NOTE: Read Operator’s Manual carefully before operating this

unit. Always be sure to place the generator on a level surface,

locking the wheel with the brake and/or blocking the wheels.

(Fig. 7)

1. Make sure all appliances are disconnected from the

generator.

2. Turn engine switch to the “ “ (CHOKE) position (Fig. 8).

(When the engine is warm or temperature is high, start engine

with the switch at “ “ (RUN) position).

3. Insert the key into the key switch and turn it clockwise to the

I “ (ON) position to start the engine. Then turn the key further

to the “ “ (START) position. The engine will started by the

starting motor.

CAUTION: DO NOT CONNECT APPLIANCES WITH

DEFECTIVE LINES AND/OR PLUGS.

BE SURE APPLIANCES ARE NOT CONNECTED

TO GENERATOR WHEN STARTING UP.

STARTING THE GENERATOR WITH AN

APPLIANCE CONNECTED COULD RESULT IN

DAMAGE TO THE GENERATOR AND/OR

APPLIANCE AND PERSONAL INJURY.

DO NOT TURN THE STARTING MOTOR OVER 5

SECONDS CONTINUOUSLY. IF THE ENGINE FAILS

TO START, RETURN THE KEY TO THE “ I “ (ON)

POSITION AND WAIT ABOUT 10 SECONDS THEN

START AGAIN.

DO NOT TURN THE KEY SWITCH TO THE “ “ (START)

POSITION WHEN THE ENGINE IS RUNNING TO

PREVENT DAMAGE OF STARTING MOTOR.

4. After 20 to 30 seconds of warm-up is completed, turn the engine

switch to “ “ (RUN) position. (Fig. 10)

5. Check to make sure the generator voltage is operating at normal

levels by changing over the LED screen in the multi monitor into

the “V” indication. Normal level is approximately 120V.

NOTE: Please contact an authorized John Deere Dealer if the

multi monitor is off during the proper operation.

6. Test the GFCI receptacle on the unit. Push the test button. The

reset button should pop out and there should be no power at

the receptacle. Apply a test load or lamp to each receptacle to

verify. IF THE RESET BUTTON DOES NOT POP OUT, DO

NOT USE THE RECEPTACLE. SEE DEALER FOR SERVICE

IMMEDIATELY.

7. If GFCI receptacle tests correctly, firmly push the reset button

to restore power. A distinctive click should be heard or felt when

this is complete. IF THE RECEPTACLE DOES NOT RESET

PROPERLY, DO NOT USE THE RECEPTACLE. SEE DEALER

FOR SERVICE IMMEDIATELY.

8. Loads can now be applied to unit.