ANSI/NFPA 70. The disconnecting means must be readily accessible

to the spa’s occupant but installed at least 5 feet (1.5m) from spa

water.

7. The electrical circuit supplied for the spa must include a suitable

ground fault circuit interrupter (GFCI) as required by NEC/USA Article

680-42.

8. To gain access to the spa’s power terminal block, remove the screws

securing the synthetic cabinet panel under the control panel (Figure

A). Then remove the four control box door screws and door (Figure B).

9. Select the power supply inlet you want to use (Figure A). Feed power

cable to control box, then install it through the large opening provided

in the bottom side of the box.

10. Connect wires, color to color, on terminal blocks TB1 and TB3

(Figure C, page 17). TIGHTEN SECURELY! All wires must be

hooked up securely or damage could result.

11. Install control box door and screws and reinstall the cabinet side

panels.

Figure a

equipment area

10

4

3

7

1

2

2

Flow

Note: Pump Locations Vary by Model

Circulation Pump

Behind Load Box

8

5

6

6

9

11

1. Control Box

2. Power Supply Entrance(s)

3. 2-Speed Jets Pump #1

4. Heater

5. Spa Drain Valve

6. Pump Drain Plugs(s)

7. 1-Speed Jet Pumps #2

8. Circulation Pump

9. Optional CD Ozonator (Purchase

Separately)

10. Factory Installed Ozone Injector

11. Control Panel

16