6 panel flashes fl1 or fl2, 7 panel displays oh, 8 panel displays (- - -) – Jacuzzi J - 355 User Manual

Page 43: J-300 series, Warning

Advertising
background image

39

J-300 series

J-300 Series

14.6 panel Flashes Fl1 or Fl2

A flashing “FL1” display means the flow switch is

malfunctioning open, the filter cartridge is excessively

dirty or an “air lock” condition has occurred at the

circulation pump intake. A flashing “FL2” display means

the flow switch is malfunctioning closed. In either case,

the spa heater will deactivate and jets pump #1 may

also deactivate. To correct condition perform the following:

1. Verify water level is above all jets but below lowest pillow. Add water

if necessary.

2. Check for clogged or dirty filter cartridge (sec. 12.1, page 30).

3. Purge “air lock” from circulation pump intake by removing filter

cartridge. Hold your garden hose over the filter cartridge wall fitting

while using a rag as a seal around hose end. Ask a helper to turn

on water for 30 seconds, then turn off. Reinstall filter cartridge and

check spa (sec. 12.1, page 30).

4. If the circulation pump is not running, turn power off at the main

breaker, then turn power back on. This will reset the circulation pump

priming cycle. Once the pump is primed, the error should clear.

5. If problem persists, contact your authorized Jacuzzi dealer.

14.7 panel Displays oH

warnInG:

rIsK oF HYperTHermIa (over-HeaTInG)

Causing severe inJury, burns, or welts.

!

Water temperature is above acceptable limits.

Do noT enTer spa!

Water temperature has reached 112 ˚F (44 ˚C) and the low

speed jets pump 1 and optional circulation pump (when

equipped) has activated to circulate water through heater.

Contact your authorized Jacuzzi dealer or qualified service technician.

To correct condition:

Remove the spa's cover and allow your spa to cool down.

Program the filter settings for Economy Mode (page

28). Raise water

temperature setting to cancel Summer Logic condition (page 38).

If the condition persists, contact your authorized Jacuzzi dealer.

14.8 panel Displays (- - -)

warnInG:

rIsK oF HYperTHermIa (over-HeaTInG)

Causing severe inJury, burns, or welts.

!

Water temperature is above acceptable limits.

Do noT

enTer spa! The safety “Watchdog” software has been

triggered and the spa is deactivated. A problem has been

detected which could cause damage to the spa or its components.

Contact your authorized Jacuzzi dealer or qualified service technician.