0 error conditions/error messages, 1 summer logic, 2 panel displays col – Jacuzzi J - 355 User Manual

Page 42: 3 panel displays ice, 4 panel displays sn1, 5 panel displays sn2

Advertising
background image

38

J-300 Series

14.0 error Conditions/error Messages

Your spa has a self-diagnostic control system. The system will

automatically display the following if a problem is detected.

14.1 summer logic

When the actual spa water temperature reaches 2 °F

(1 °C) above the set temperature, the spa goes into

“summer logic.” The 24-hour circulation pump will turn off

automatically to avoid adding additional heat to the water,

eventually creating an overheat condition. This setting is

not user-programmable.

note: Summer logic does not take effect until the spa water temperature

reaches 95 °F (35 °C). This condition is more likely in excessively hot

weather. Remember, the spa’s ability to cool is directly affected by

the ambient temperature. An excessively hot ambient temperature

may prevent the spa from cooling down because it’s fully insulated

construction is designed to retain heat and minimize operating costs.

14.2 panel Displays Col

Cool Condition - Temperature has dropped 20 °F (11 °C)

below the current set temperature. Jets pump 1 and the

heater have been activated to bring the temperature within

15 °F (8 °C) of the set temperature. No corrective action is required!

note: This condition is common during first time fill ups or during refills

since tap water is often very cold.

14.3 panel Displays ICe

Freeze Protection - A potential freeze condition has been

detected. No action is required. Jets Pump 1 and heater

will activate to circulate and warm water through the plumbing until spa is

out of danger. See “Winterizing” (page 35).

14.4 panel Displays sn1

Open sensor (heater is disabled) or shorted sensor (spa

is deactivated). The high-limit temperature sensor is not

functioning. Contact your authorized Jacuzzi dealer or

qualified service technician.

14.5 panel Displays sn2

Open or shorted sensor (heater disabled). The

temperature sensor is not functioning. Contact your

authorized Jacuzzi dealer or qualified service technician.

38

Advertising
This manual is related to the following products: