0 automatic filtration cycles, 1 standard filtration/heating modes (f0-f3), 2 economy filtration/heating modes (f4-f6) – Jacuzzi J - 355 User Manual

Page 32: 3 lock modes (l1-l2), 4 selecting the filtration/heating mode

Advertising
background image

28

J-300 Series

11.0 automatic Filtration Cycles

Your new spa includes a 24-hour circulation pump which filters the water

continuously. The circulation pump draws water through the skimmer bag

and one of two filter cartridges to effectively remove small debris in your spa.

note: The 24-hour circulation pump system also supplies heated water

to the spa when the heater turns on. The pump is not programmable.
The control system activates a programmable “standard” or “economy”

filtration/heating cycle to remove larger debris missed by the 24-hour

circulation pump filtration system. These cycles utilize pump #1 low

speed and the second filter cartridge to quickly “skim” the water of large

debris and minimize their “bath-tub ring” effect. Apart from their skimming

benefit, each mode also effects the operation of your spa’s heater. Refer

to Sections 11.1 and 11.2 below for additional information.
11.1

standard Filtration/heating Modes (F0-F3)

Standard filtration/heating modes are typically selected by customers in

cold climates where heat up times are extended due to lower ambient

temperatures. In these modes, the water temperature is regulated by the

set temperature, 24-hour circulation pump, and heater which turns on as

needed. After the programmed set temperature is reached, the heater

turns off and the circulation pump continues to operate 24-hours to filter

and clean your spa unless in summer logic; see Section 14.1, page 38.
11.2

economy Filtration/heating Modes (F4-F6)

Economy filtration/heating modes are typically selected by customers in

warm climates where heat up times are minimized due to higher ambient

temperatures. In these modes, the water temperature is regulated by

the set temperature, 24-hour circulation pump, and heater only while a

programmed filter cycle is running (unless in summer logic; see Section

14.1, page 38).

11.3

lock modes (l1-l2)

These modes are designed for use during spa service or to prevent

unauthorized use.

11.4

selecting the Filtration/heating Mode

Press and hold both control panel WARMER ( ) and COOLER ( )

buttons at the same time, then release. Then press either WARMER

( ) or COOLER ( ) button to select filtration/heating mode F0-F6 or

lock modes L1-L2 below: