Connections, Basic system (a mode), Setting procedure – JVC RM-P2580 User Manual

Page 19: Timelapse vcr rm-p2580, Id:1 id:2 id:3, Master monitor, Rec stop rec check eject operate operate, Preset positions ( ref. : page 27), Camera 1, Set pin 1 to "off" for a mode

Advertising
background image

19

1

TO CAMERA

TO CAMERA

DATA I / O

DATA I / O

RX

RX+ RX

RX- TX

TX+ TX

TX-

COM

COM

1

2

3

4

5

6

7

8

COM

COM 9/1

9/1 10/2

10/2 11/3

11/3 12/4

12/4 13/5

13/5 14/6

14/6 15/7

15/7 16/8

16/8 COM

COM

COM

COM

COM

COM

CAMERA

CAMERA

SW

SW

UNIT

UNIT

ALARM

ALARM

AUTO

AUTO

4

3

1 2

8

7

5 6

2

3

4

5

6

7

8

1

MONITOR

MONITOR

OUTPUT

OUTPUT

MONITOR

MONITOR

SERIAL-2

SERIAL-2

SERIAL-1

SERIAL-1

VIDEO INPUT

VIDEO OUTPUT

VIDEO OUTPUT

OUTPUT

OUTPUT

2

1

ON

ON

2

3

4

5

6

7

8

POWER

OFF

ON

AC INPUT

V.IN

MONITOR
OUTPUT 2

MONITOR
OUTPUT 1

CAM SW
OUT

VIDEO

IN

COM

CAMERA

SW

AC24V

AC24V

AC24V

TO

CAMERA

TIMELAPSE VCR

RM-P2580

CAMERA 1

CAMERA 1

CAMERA 1

ID:1

ID:2

ID:3

Camera 1

video

Camera 2

video

Camera 3

video

Camera 4

video

Camera 5

video

Camera 6

video

Camera 7

video

Camera 8

video

MASTER MONITOR

Set Pin 1 to "OFF" for A Mode.

REC

REC

STOP

REC

CHECK

EJECT

OPERATE

OPERATE

4. CONNECTIONS

BASIC SYSTEM (A MODE)

This system accepts video signals from the cameras via the VIDEO INPUT connectors.
Up to 8 cameras can be connected in this system.

Setting Procedure

1.

Connect all the equipment.
(All the cameras must be synchronized).

2.

Set the system mode selection to A Mode, and set
the rear DIP SW1 to "OFF".

3.

To set a camera ( REF. : Instructions Manual of
the camera being used)
· Match the ID with the VIDEO INPUT number.
· Set to MULTIDOROP or DUPLEX

4.

Preset positions ( REF. : page 27)

5.

To change the setting values of the system in use
· CAMERA SELECTION: AUTO ( REF. : page 29)
· CAM SWITCH: LOW ( REF. : page 30)

6.

Operational setting values can be changed as re-
quired.
· P/T SPEED: 8 STEPS ( REF. : page 29)
· AUTO SEQUENCE SCREEN TIME: 2 SEC ( REF.

: page 32)

7.

Check the ALARM INPUT time set value.
· DATA I/O screen: 16ALM IN ( REF. : page 30)
· ALARM screen: ( REF. : page 32)

8.

ALARM INPUT TIME setting required for each cam-
era
·TERMINAL item ( REF. : page 31)