Rear panel connectors to camera, Serial-1, -2, Dip switch – JVC RM-P2580 User Manual

Page 23

Advertising
background image

23

The electrical standards applied to the SERIAL-1 and SERIAL-
2 connectors can be switched between RS-232C and RS-422A
using pins 7 and 8 of the rear panel DIP switch.

4. CONNECTIONS

REAR PANEL CONNECTORS

TO CAMERA

Connection to control the camera. (The RM-P2580 is compatible with a TK-C675B camera.)
Communication is carried out by MULTIDROP FULL DUPLEX (RS-485, FULL DUPLEX).

SERIAL-1, -2

Connect a frame switcher, etc.
(D-sub 9-pin, male connectors)

R X +

R X –

T X +

T X –

A

B

C

D

RM-P2580

CAMERA 1

T X +

T X –

R X +

R X –

T X +

T X –

R X +

R X –

CAMERA 2

Attach or remove each cable by pushing
down and holding each terminal connector,
as shown above.

Hold.

RX+ RX-

TX-

TX+

A

B

C

D

A

B

C

D

5

9

1

6

DIP SW

7

8

Set

Connector

SERIAL-1

SERIAL-2

OFF

RS-232C

RS-232C

ON

RS-422A

RS-422A

Pin No.

Signal Name

1

2

3

4

5

6

7

8

9

NC

RXD (Data input)

TXD (Data output)

DTR (Control output)

GND

DSR (Control input)

RTS (Control input)

CTS (Control output)

NC

Pin No.

Signal Name

1

2

3

4

5

6

7

8

9

NC

RXD- (Data input)

TXD- (Data output)

NC

GND

NC

TXD+ (Data output)

RXD+ (Data input)

NC

Signals when the RS-232C is set

Internally connected.

Internally connected
via a driver.

Signals when the RS-422A/485 is set

Internally connected.

Set the mode and select the electrical standard for the SERIAL connector.

DIP Switch

4

3

1 2

8

7

5 6

ON

(Default: All OFF)

Description

OFF

ON

Pin No.

1
2

|

6
7
8

System mode selection
Cannot be used.
(Ensure that they are set to OFF.)

SERIAL-1 electrical standard selection
SERIAL-2 electrical standard selection

A mode

RS-232C
RS-232C

B mode

RS-422A
RS-422A

Note

Communication speed is 9600 bps.

Advertising