Vent windows for propane, Ad c c, Coaxial vent colinear vent – Jotul GF300 DV User Manual

Page 11

Advertising
background image

11

HORIZONTAL RUN

35 Ft.

(10.67 m)

30 Ft.

(9.14 m)

25 Ft.

(7.62 m)

20 Ft.

(6.10 m)

15 Ft.

(4.57 m)

5 Ft.

(1.52 m)

Min. Rise

2 Ft.

(.60 m)

10 Ft.

(3.05 m)

5 Ft.

(1.52 m)

VERTICAL

RUN

15 Ft.

(4.57 m)

20 Ft.

(6.09 m)

27 Ft.

(8.22m)

12 Ft.

(3.65 m)

8 Ft.

(2.43 m)

A

D

C

C

Min. Vertical

Termination

Up to four 45° or

two 90° elbows

permitted in

addition to the

starter elbow.

Figure 11. Coaxial Vent Termination Window / LP

Figure 12 . Colinear Termination / LP

Vent Windows for Propane

COAXIAL VENT

COLINEAR VENT

• VENTING MUST

TERMINATE (END) WITHIN

THE SHADED AREA.

• Adjust the Exhaust

Restrictor to position C for
a vertical colinear
termination.

• Max. Offset: 2 ft. (610 mm)

• VENTING MUST TERMINATE (END) WITHIN ONE OF THE

DESIGNATED AREAS.

• SET STOVE EXHAUST RESTRICTOR TO THE POSITION THAT

CORRESPONDS TO THE VENT TERMINATION AREA IN THE

DIAGRAM ABOVE.

• ALWAYS MAINTAIN THE PROPER CLEARANCES TO

COMBUSTIBLES.

The circled letter designations in the vent diagram correspond
to the Exhaust Restrictor Setting on the stove. First, determine
which vent termination zone is appropriate for your installa-
tion and fuel type, then adjust the stove restrictor plate to the
corresponding position as shown in Figure 7, page 9.

35 Ft.

(10.67 m)

25 Ft.

(7.62 m)

2 Ft.

(16 cm)

VERTICAL

RUN

Minimum

Vertical

Termination

8 Ft.

(2.43 m)

45°

Elbow

Up

HORIZONTAL RUN

C

Advertising