Stove and vent clearance requirements, Alcove installation, Minimum clearances from the stove to combustibles – Jotul GF300 DV User Manual

Page 7

Advertising
background image

7

Alcove Installation

Maximum Alcove Depth:

24” (610 mm)

Minimum Alcove Width:

36 3/4” (934 mm)

Minimum Ceiling Height:

61” (1549 mm)

With Short Legs (6”): 58 3/4 (1486 mm)

* Allow 10” on left side of the appliance for complete

access to the lighting instructions and control valve.

3”

(76mm)

Right Side

Figure 3. Parallel Installation Clearances.

Figure 4. Vent adaptor centerline at minimum clearance
to corner walls.

10” *

(254 mm)

Left Side

Figure 2. Mantel and Trim Clearance specifications.
Subtract 2 1/4” with Short Legs.

2”

(51 mm)

To Rear Wall

52 1/2” 1334 mm

55 1/2” 1410 mm

12.5”

10.25”

5.75”

3.5”

18 1/2”

(419 mm)

Max. Mantel Depth

Min. Mantel Depth

Minimum Ceiling or Alcove Height

61”

1550

mm

54”

1372 mm

58 1/2” 1486

mm

57”

1449

mm

28”

71

1 mm

Max. Top Trim Depth = 1”

46 1/2” 1182 mm

Stove and Vent Clearance
Requirements

Minimum Clearances from the Stove
to Combustibles:

See figs. 2-4.

Rear:

2” (51 mm)

Ceiling:

33” (838 mm)

Corner:

2” (51 mm)

Right Side: 3” (76 mm)
Left Side:

10” (254 mm)

- for access to Lighting Instruction plate

Minimum Clearances from the Vent Pipe to
Combustibles:

Horizontal Run:
Off the top of the pipe 2” (50 mm)
Off the sides and bottom 1” (25 mm)
Vertical Run:
All sides

1” (25 mm)

11”

280 mm

11”

280 mm

51 mm

51 mm