Jotul GF300 DV User Manual

Page 25

Advertising
background image

25

Optional Blower # 155371

Figure 42 . Blower Kit Components

Figure 43 . Attach Snapstat and Blower Brackets.

„

„

„

„

„

THIS BLOWER MUST BE

ELECTRICALLY GROUNDED IN

ACCORDANCE WITH LOCAL CODES

OR, IN THE ABSENCE OF LOCAL

CODES, WITH THE CURRENT ANSI/

NFPA 70, NATIONAL ELECTRICAL

CODE OR CSA C22.1-CANADIAN

ELECTRICAL CODE.

„

„

„

„

„

THIS UNIT IS SUPPLIED WITH A

THREE-PRONG (GROUNDING)

PLUG FOR PROTECTION AGAINST

SHOCK HAZARD AND SHOULD BE

PLUGGED DIRECTLY INTO A

PROPERLY GROUNDED THREE-

PRONG RECEPTACLE. DO NOT

CUT OR REMOVE THE GROUNDING

PRONG FROM THE PLUG.

„

„

„

„

„

ALWAYS DISCONECT THE POWER

SUPPLY WHEN PERFORMING ANY

SERVICE ON THE FIREPLACE

INSERT.

Read these instructions before beginning the installation.
1. Unpack and check the contents
of the blower kit.

The kit includes two Air Deflectors and two #7 x 1/2”
screws that will not be used with the GF 300 DV
Allagash stove. Contact your dealer if any damage is
evident or parts are missing. See fig. 42.

2. Install the Snapstat by sliding it all the way into the

slot in the bottom of the Snapstat Bracket as shown
in fig. 43.

3. Attach the Snapstat Bracket to the studs located in

the middle of the firebox floor using the two M6
hex nuts and a 10 mm wrench. See fig. 43.

4. Attach the Blower Bracket to the stove using the

two M6 flange head hex bolts as shown in fig. 43.

5. Install the Blower with the duct openings oriented

up and to the rear. See fig. 44. Feed the snapstat
wire harness through the bracket opening and
secure the blower to the bracket with the
wingscrew. Route the controls wire harness over to
the female quickconnector already installed in the
stove.

6. Attach either Snapstat wire connector to either

Snapstat terminal. See fig. 44.

7. Connect the male Control Switch connector to the

female control switch wire harness already installed
in the stove. See fig. 44.

8. Connect power cord to outlet.

Contents
1. Blower
2. Mounting Bracket
3. Snapstat Wire Harness
4. Control Switch Wire Harness
5. Snapstat
6. Snapstat Bracket
7. M6 x 1 x 20 Flange Nuts (2)
8. M6 x 12 Wingscrew

5

7

2

8

4

3

1

6

Tools Required
• 10 mm wrench

Snapstat

Bracket

Blower Bracket

Hex Head

Flange Bolts

Hex Head

Flange Nuts

Advertising