Figure 22. Locate and remove the Air Shutter wingnut
from under the right side of the stove.

Tools required:
• 1/2” open ended wrench or deep-well socket, Torx T20

or slotted screwdriver, 4 mm allen wrench.

Conversion Kit Contents:
• 1, regulator tower labeled for propane
• 3, regulator tower screws
• 1, burner orifice (#39 for NG, #53 for LPG)
• 1, pilot orifice (#51 for NG, #30 for LPG)
• Label A - to be completed and applied to

the back of the stove

• Label B - apply to the stove’s Rating Plate
• Small valve label - apply to valve body

Conversion instructions are also shipped in the stove
with the conversion kit.

Mobile Home Installation

The GF 300 DV can be installed for use in a mobile home
in the U.S. and Canada provided:
1. The stove is secured to the floor of the mobile home.

Use Jøtul Floor Bracket Kit #154388.

2. Provision must be made to secure an electrical ground

between the stove and the mobile home chassis.

3. The stove is installed in accordance with Title 24 CFR,

Part 3280- Manufactured Home Construction and
Safety Standard, in the U.S. In Canada, comply with
CSA Z240.4, Gas Equipped Recreational Vehicles and
Mobile Housing.

4. Always contact your local officials about installation

restrictions and requirements in your area.

THIS APPLIANCE MAY BE INSTALLED AS AN

OEM INSTALLATION IN A MANUFACTURED

(MOBILE) HOME AND MUST BE INSTALLED IN

ACCORDANCE WITH THE MANUFACTURER’S

INSTRUCTIONS AND THE MANUFACTURED

HOME CONSTRUCTION AND SAFETY STAN-

DARD, TITLE 24 CFR, PART 3280. THIS APPLI-

ANCE IS ONLY FOR USE WITH THE TYPE OF

GAS THAT IS INDICATED ON THE STOVE’S

RATING PLATE. A GAS CONVERSION KIT IS

PROVIDED WITH THE GF 300 DV GAS STOVE.

THIS APPLIANCE MAY BE INSTALLED IN AN

AFTERMARKET PERMANENTLY LOCATED,

MANUFACTURED (MOBILE) HOME, WHERE

NOT PROHIBITED BY LOCAL CODES.

CET APPAREIL PEUT ETRE INSTALLE DANS

UN MAISON PREFABRIQUEE (MOBILE) DEJA

INSTALLEE A DEMEURE SI LES REGLEMENTS

LOCAUX LE PERMETTENT. CET APPAREIL

DOIT ETRE UTILISE UNIQUEMENT AVEC LES

TYPES DE GAS INDIQUES SUR LA PLAQUE

SIGNALETIQUE. NE PAS L’UTILISER AVEC

D’AUTRES GAS SAUF SI UN KITDE CONVER-

SION CERTIFIE EST INSTALLE.

Fuel Conversion

The GF 300 DV gas stove is shipped from the factory
equipped to burn NATURAL GAS only. If PROPANE gas is
to be used as fuel, the appliance must first be converted
for use with propane. Use Propane Conversion Kit
155372, supplied with the appliance.

Order and install NG Conversion Kit 155373 to

change back to use with natural gas.

WARNING:

THE CONVERSION KIT IS TO BE

INSTALLED BY AN AUTHORIZED JØTUL

SERVICE TECHNICIAN IN ACCORDANCE

WITH THE MANUFACTURER’S

INSTRUCTION AND ALL CODES AND

REQUIREMENTS OF THE AUTHORITY

HAVING JURISDICTION. FAILURE TO

FOLLOW THESE INSTRUCTIONS COULD

RESULT IN SERIOUS INJURY OR

PROPERTY DAMAGE. THE QUALIFIED

AGENCY PERFORMING THIS WORK

ASSUMES RESPONSIBILITY FOR THIS

CONVERSION.

IN CANADA:

THE CONVERSION SHALL BE CARRIED

OUT IN ACCORDANCE WITH THE RE-

QUIREMENTS OF THE PROVINCIAL AU-

THORITIES HAVING JURISDICTION AND

IN ACCORDANCE WITH THE REQUIRE-

MENTS OF THE CAN1-B149.1 AND .2

INSTALLATION CODE.