Horizontal Termination

„

Any horizontal termination must fall within the
shaded portion of the vent window graph illustrated
in figs. 9 or 11. For Snorkel Terminations, see below.

„

Any horizontal termination except a snorkel termination,
must include:
1)

Minimum rise of 24 in.

2)

Minimum horizontal run of 12 in. when vertical
run is less than 8 ft.

3)

Vertical run no more than 35 ft.

4)

Horizontal run no more than 27 ft.

5)

No more than four 45° or two 90° Elbows

„

The horizontal termination cap must maintain a 3"
clearance to any overhead combustible projections
2 1/2" or less. It must also maintain 12" clearance
from projections exceeding 2 1/2". See fig. 21.

„

Wall Cut-out Opening: A minimum 10" X 10" (250 mm x
250 mm) square hole is required for proper pipe clear-
ances through a combustible wall.

DO NOT FILL AIR SPACE WITH ANY TYPE OF INSULATION.

„

Any horizontal run of vent must be level or have a
1/4 in. rise for every foot of run toward the termina-
tion cap. NEVER ALLOW THE VENTING TO RUN DOWN-
WARD FROM STOVE TO TERMINATION; DOWNWARD
VENT RUNS TRAP HEAT AND CAUSE HIGH TEMPERA-
TURES TO DEVELOP WITHIN THE VENT THAT COULD
START A FIRE.

„

Install a Vinyl Siding Standoff (Simpson Dura-Vent
#950) between the vent termination and an exterior
wall covered by vinyl siding material to prevent
potential heat damage to the siding.

„

Do not recess the termination cap into a wall or
siding.

Figure 17.
• Minimum vent for horizontal termination.
• 14” Maximum horizontal run directly off rear of stove

with 14” Snorkel termination.

Figure 18. Maximum Horizontal with 36” Snorkel Termination.

Figure 19. Corner Installation with 14” Snorkel Termination.

Snorkel Terminations

„

With a 14” Snorkel:
The horizontal run made directly off the rear of the
stove into a 14” snorkel cap should include no more
than a single 12” straight section as shown in fig. 17.
One 45° Elbow may be used for a corner installation as
shown in fig. 19.

„

With a 36” Snorkel:
The maximum horizontal run may be no more than
6 ft. (182 cm.)

12 in.

Straight Pipe

Max.

14”

355 mm

Wall Thimble

and Trim Collar

45° Elbow

See Note F

Fig. 20

Max.

6 ft.

183 cm

36 in.

Snorkel

(915 mm)

CL

25”

635 mm

56 1/2”

1435 mm

14”

335 mm

Max.

12”

vent

pipe or

less

12”

305

mm

24”

610 mm