Co-linear vent installation – Jotul GF300 DV User Manual

Page 12

Advertising
background image

12

Co-linear Vent Installation

The GF 300 DV may be vented through a masonry or
Class A prefabricated chimney using a Co-linear Flexible
Vent system approved for use with a solid-fuel burning
fireplace. When installed in the manner described below,
this system can improve the performance of the appli-
ance in cold climate situations, as well as simplify the
vent installation. See fig. 14.
These installation requirements must be followed:
1. Use the guidelines for Co-linear Vent Termination

appropriate for your gas type on pages 10 - 11.

1. Prior to the installation the chimney flue must be

thoroughly cleaned and inspected by a qualified
chimney service person.

2. In a masonry chimney, a fireclay liner must be present

the entire length of the chimney.

3. Prefabricated chimneys must be UL 103 or ULC S-629

listed and have a minimum INSIDE diameter of 6
inches, (150 mm).

4. No appliance can be installed into a chimney flue

serving any other appliance of any kind.

5. THE AIR INTAKE FLEX PIPE MUST EXTEND 6 FEET

BEYOND THE DAMPER AREA OF THE FIREPLACE.

6. If the intake flex duct does not extend the full length

of the chimney and connect to both the unit and the
termination cap, A METAL BLOCK OFF PLATE MUST BE
CONSTRUCTED AND INSTALLED ABOVE THE UNIT
PRIOR TO THE END OF THE INTAKE FLEX AND MUST
COMPLETELY SEAL THE CHIMNEY FLUE FROM THE
ROOM.

Consult with the local code authority having juris-

diction before proceeding with this type of installation.

Refer to the vent manufacturer’s instructions for

specific installation requirements.

WARNING: FAILURE TO POSITION THE PARTS AND

STOVE IN ACCORDANCE WITH THESE DIAGRAMS OR
FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED
FOR USE WITH THIS APPLIANCE MAY RESULT IN PROP-
ERTY DAMAGE OR PERSONAL INJURY. BE SURE TO
MAINTAIN THE PROPER CLEARANCES TO COMBUSTIBLES
AS DEFINED IN THIS MANUAL AND IN THE INSTRUC-
TIONS PROVIDED WITH EACH VENT COMPONENT.

Figure 14. Co-linear Adaptor installed through a masonry
chimney. Simpson Dura-Vent components shown.

Figure 15. Simpson Dura-Vent #923GCL Co-linear Adaptor.
Subtract 2 1/4” for Short Legs.

Max. offset

24”

(609 mm)

The Air

Intake Flex

pipe must

extend 6

feet beyond

the damper.

The chimney

must be sealed

off from the

room by a steel

plate at the

damper area.

#991 High

Wind Cap

Exhaust Gas

Intake Air

Max. Co-linear

Height - 35 ft.

(10.66 m)

Min. Co-linear

Height - 8 ft.

(2.44 m)

Dual 3”Flex

Liners

28 3/4”

to top of

Co-linear

Adapter.

25”

to center

of flue

collar

Advertising