9-2

Sun Fire V120 and Netra 120 Server User’s Guide • December 2001

9.1

Monitoring the System From Solaris

To use the Lights-Out Management (LOM) facilities either remotely or locally, you
need a terminal connection to the Serial A/LOM port on the server (see Chapter 6).

There are two ways of interrogating the LOM device or of sending it commands to
perform.

■

One is by executing LOM commands from the

lom>

shell prompt. For

information about how to do this, see Chapter 8.

■

The other is by executing LOM-specific Solaris commands from the Solaris
prompt. These commands are described in this chapter.

The Solaris commands described in this section are all available from the main
Solaris # prompt. They run a utility called

/usr/sbin/lom

.

Where appropriate, the command lines given in this section are accompanied by
typical output from the commands.

9.1.1

Viewing Online LOM Documentation

●

To view the manual pages for the LOM utility, type:

9.1.2

Checking the Power Supply Unit (

lom -p

)

●

To check that the input lines and the output line for the power supply unit are
working normally, type:

# man lom

# lom -p

PSUs:

1 OK

#

Advertising