To configure the LOM device to perform an automatic server restart (ASR) after a
lockup, you must enable the

Hardware reset

option as well as the

Watchdog

option. For information about how to do this, see Section 9.2, “Configuring
Automatic Server Restart (ASR)” on page 9-8.

9.1.8

Viewing the Configuration of the LOM Device
(

lom -c

)

To view the settings of all the configurable variables for the LOM device, type:

9.1.9

Viewing All Component Status Data With the
LOM Device’s Configuration Data (

lom -a

)

To view all the status data stored by the LOM device plus the details of the
device’s own configuration, type:

# lom -c

LOMlite configuration settings:

serial escape character=#

serial event reporting=default

Event reporting level=fatal, warning & information

Serial security=enabled

Disable watchdog on break=disabled

Automatic return to console=disabled

alarm3 mode=watchdog

firmware version=3.0

firmware checksum=2983

product revision=0.0

product ID=120

#

# lom -a