Replacing the rear fan subassembly (fans 1 and 2), Section 11.8, “replacing the rear fan – Sun Microsystems Netra 120 User Manual

Page 173

Advertising
background image

Chapter 11

Replacing a Server or Replacing Individual Components

11-19

11.8

Replacing the Rear Fan Subassembly
(Fans 1 and 2)

Caution –

The procedure below is for the attention of qualified service engineers

only. Before touching or replacing any components inside the server, disconnect all
cables and follow the instructions in Section 4.2, “Opening the Server” on page 4-4
which tell you how to open the server. Always place the server on a grounded ESD
pad and wear a properly grounded antistatic wrist strap.

1. Open the server by following the instructions in Section 4.2, “Opening the

Server” on page 4-4.

Make sure you disconnect all external cables and pay particular attention to the
information about how to prevent electro-static discharge from your body from
damaging the components of the server.

2. With the server open and seated on top of an ESD pad, and with a properly

grounded antistatic wrist strap on your wrist, disconnect the old subassembly’s
power cables from the system board (see

FIGURE 11-10

).

3. Lift out the old subassembly and discard it.

4. Insert the new fan subassembly into its bay in the chassis.

5. Connect the fan cables to the system board (see

FIGURE 11-10

).

6. Replace the server’s cover and tighten the captive screw (see

FIGURE 4-9

in

Section 4.7, “Replacing the Server’s Top Cover” on page 4-14).