Sharp AR-407 User Manual

Page 98

Advertising
background image

5-10

CHAPTER

5

Paper feed area open/close lever

3

Remove the misfed paper from the section below the exit area.

3

Close the exit area cover.

4

Open and close the front cover to cancel the misfeed
display.

If the misfed paper is in the right side of the duplex module:

1

Open the right side cover.

Hold the handle and gently open the cover.

If any paper is set in the bypass tray, remove the paper and close
the bypass tray before opening the right side cover.

2

Remove the misfed paper.

Open the paper feed area open/close lever in the direction of the
arrow and remove the misfed paper.

3

Close the right side cover.

4

Open and close the front cover to cancel the misfeed
display.

Confirm that the misfeed display is cleared.

COPIER TROUBLE?

Misfeed removal

MISFEED REMOVAL

Advertising