DAW Control GuidE

3 - 1 6

Duality Operator’s Manual

Notes on Scrub and Shuttle Modes

The position at which the scrub/shuttle starts is derived from the current DAW selection or timeline position.

Scrub/Shuttle mode can commence from the selection end point by holding down the OPTION button before you

grab the shuttle wheel.

Holding down the ALT button will increase the resolution of the scrub/shuttle wheel.

When scrub or shuttle is active, many functions are suspended until you exit from scrub/shuttle mode. The

following functions are available:

Fader control, solo and cut buttons

Scrub/Shuttle wheel functions

Transport controls

Enter button (to create marker/cue events)

Scrub/Shuttle will also control serial machines if the DAW is 9-pin enabled.

Numeric Keypad (18)

The console’s numeric keypad replicates the numeric keypad on a DAW keyboard. The primary use for this

keypad is for saving and recalling Memory Locates and entering data values (please refer to your DAW manual

for more details on keypad uses).

Working with Markers/Memory Locations

To Enter a Marker/Cue point, press ENTER. To Recall a Marker/Cue point, press a number followed by the

decimal point button (Numeric Keypad in Classic mode) or a decimal point followed by a number followed a

decimal point (Numeric Keypad in Transport mode).

The ENTER button on the keypad also works as a enter button for pop-up windows,

duplicating the ENTER button on the Master Control Panel