Overview

The Multi-user Total Recall (TR) package is a chargeable option for the Duality console. If not supplied with

your console, please contact your nearest SSL representative for details.

The system uses the channel meter display screens in each bay to give a graphical display of current and

stored control settings for all rotary controls, faders and switches on Duality’s channel strips and centre section

modules. Controls that are in different positions from the stored values are highlighted in yellow, and may be

reset manually to the stored settings. Electronically latched switches such as EQ, Insert, Dynamics and Cut

buttons can be reset to match the stored setup by pressing the fader status button twice. Pressing the SET

ALL soft key twice will reset all the soft button functions. Pressing the SET SEL key twice will reset the soft

buttons on all channels currently selected on the Central Routing Panel.

Each bay screen is used to display the settings for one channel (or the centre section), thus allowing multiple

channels to be reset at the same time.

Stored TR setups can be copied or swapped between channels by holding down the fader status button on the

source channel then pressing the fader status button on the destination channel. If the soft COPY button (see

later) is selected, the source channel settings are copied to the destination channel; if not, the source and

destination channel settings are swapped.

TR setups are saved within Duality’s Projects system and stored locally in Duality’ flash memory. Setups may

then be copied to an appropriate folder on your DAW. See Copying TR Setups to a DAW Folder.

Duality Operator’s Manual

4 - 1

Total Recall

S e c t i o n 4 – T o t a l R e c a l l