background image

1-21 (E)

BKP-7933

Changing the Operation Mode of the RCP PREVIEW Switch

The operation mode of the RCP PREVIEW switch can be changed on the CNU-700 character display.

Use the switches on the AT board inside the CNU-700 for this setting.

1.

Set the MODE switch to 5.
The message “INTERNAL MODE SETTING” appears on the character monitor display.

2.

Set the SET/CANCEL switch to the SET position. The INTERNAL MODE SETTING display
appears.

3.

Select “RCP preview MOMENTARY & ALTERNATE” with the UP/DOWN switch. Set the SET/

CANCEL switch to the SET position.

4.

Select the desired operation mode (MON/ALT/ALT1) with the UP/DOWN switch. Set the SET/

CANCEL switch to the SET position. Each operation mode is described below.
MON: The preview display appears only while the RCP PREVIEW switch is being pressed.

ALT:

The preview display appears when the RCP PREVIEW switch is pressed once, and disap-
pears when it is pressed again.

ALT1: The preview display appears when the RCP PREVIEW switch is pressed once but cannot be

turned off.

(If the PREVIEW switch is turned on from another RCP, the preview display can be
switched.)

5.

Set the MODE switch to 0.

1-7. Setting Up

AT

+5

MODE

SET

UP

DOWN

CANCEL

CHARACTER

PHASE

SET/CANCEL switch

UP/DOWN switch

MODE switch

OFF

Page9,11-Link cancel

OFF

RCP preview MOMENTARY & ALTERNATE

1 : MON

2 : ALT

3 : ALT1

OFF

OFF

OFF

INTERNAL MODE SETTING