Sony BKP-7933 User Manual

Page 39

Advertising
background image

1-33 (E)

BKP-7933

1-7-10. Returning the Setups of the MODIFICATION COMMAND to the Factory

Default Values

1.

Select “K: RESET TO DEFAULT TABLE” using the

cursor key and press [ENTER].

2.

The message “Reset to Default table?” appears in the

bottom right of the screen. Select “Y” and press
[ENTER].

SONY ROUTING SYSTEM SETUP MENU BKP-7933 V1.00 STATION NUMBER 2

MODIFICATION COMMAND

A: SET UNIT LOCATION(CAM-CCU) B: SET UNIT LOCATION(CCU-RCP)

C: SET UNIT LOCATION(MSU)

K: RESET TO DEFAULT TABLE

MAINTENANCE COMMAND

Z: BKP-7933 CONFIGURATION

Ctrl-D RETURN

1-7-11. Returning the Setups of the MAINTENANCE COMMAND to the Factory

Default Values

1.

Establish the following setup of the switch S2 on the

IF-689 board depending upon the type (analog/digital)
of routing switcher.

S2-1:

When the analog routing switcher (BVS-V3232) is used

ON

When the digital routing switcher (DVS-V1616) is used

OFF

S2-2 to S2-8: OFF

Factory default setting :

All OFF

2.

Set the switch S5 on the IF-689 board as shown below.

S5-1 to S5-3:OFF

S5-4:

ON

S5-5:

ON

S5-6 to S5-8:OFF

Factory default setting:

All OFF

3.

Turn on the main power of the CNU-700, or press the
RESET switch S1.
n
All data is initialized in about five seconds.

4.

Set the switch S5 to the factory default position.

1-7. Setting Up

IF

RX TX

S-BUS

S-BUS ID No.

S5

S2

S1

CNU GROUP No.

+5

(Component side/A side)

IF-689 board

1

8

7

6

5

4

3

2

( indicates the switch lever position)