Function, Code, Outline – Star Micronics DOT MATRIX PRINTER SP2000 User Manual

Page 45

Advertising
background image

43

n2

Treatment of missing data during reverse mode

“0” to “7”

Store

“8” to “F”

Delete

*1:

Valid only when using a parallel interface.

Set DIP SW 1-2 if you are using a serial interface.

Also, the conditions for BUSY and the automatic status are

disregarded.

*2:

Valid only when using a parallel interface.

For example, if you exit the reverse mode without the host

receiving the trailing data of the automatice status the

remainder of the status data will be handled as described

below.

Store:

Stores the remaining data and transmits it at the

next time the reverse mode is entered. If the

automatic status occurs, the new status will be

transmitted after that remaining data.

Delete:

Deletes the remaining data. It does not transmit

that data the next time the reverse mode is

entered. The new status data is transmitted from

the header field.

FUNCTION

Initialize printer

CODE

<ESC> “@”

(1B)H (40)H

OUTLINE

Initializes all the commands already set. However the following

parameters are not initialized: online switch valid/invalid

selection. Also, the line and data buffers are not cleared. The

DIP switches and the memory switches are not read in again.

The select/deselect state for addressable mode and DC1/DC3

mode is not affected.