Setting System Frequency / Setting Timecode

Chapt

er

3

Pre

par

at

ion
s

Setting System
Frequency

This unit can record and play back video at the system
frequencies of 59.94i, 50i, 29.97P and 25P (1080) or
59.94P and 50P (720).
Selecting the system frequency

1

Set setup menu item 013 SYSTEM FREQUENCY
SELECT MENU to “on” and press the PUSH
SET(S.SEL) knob.

The system frequency selection screen appears.

2

Turn the PUSH SET(S.SEL) knob to select the system
frequency to be used.

3

Press the PUSH SET(S.SEL) knob or the SAVE
function button (F5).

The message “Turn off/on POWER!!” appears.

4

After pressing the on/standby button to power off the
unit, power it on again.

Setting Timecode

There are the following four ways of recording timecode:
Internal Preset mode: This records the output of the

internal timecode generator, set beforehand to an
initial value. The following run modes can be
selected.
• Free Run: Timecode advances continually.
• Rec Run: Timecode advances only during

recording.

Internal Regen mode: This records the output of the

internal timecode generator, initialized to timecode
following continuously upon the timecode of the last
frame of the last clip on the disc.

External Regen mode: This records the output of the

internal timecode generator, synchronized to an
external timecode generator. As the external input, the
timecode input to any of the following connectors can
be selected.
• TIME CODE IN connector: LTC
• SD/HDSDI INPUT connector: VITC and LTC

(i.LINK) S400 connector: TC

External Preset mode: This directly records the input of

an external timecode generator. As the external input,
the timecode input to any of the TIME CODE IN
connector can be selected.

To record timecode after setting an initial
value (Internal Preset)

Proceed as follows with the function menu. For setting the
timecode, set TCG on page P5 TC of the function menu to
INT and PRST/RGN to PRESET.

Setting an initial timecode value

1

Press the CNTR SEL function button on the HOME
page of the function menu, and select TC.

RETURN

-

+

SAVE

SETUP

EXIT

SYSTEM FREQUENCY

SELECT

1080/59.94i

If the System Frequency

setting is changed,

Turn power off and on

again.

RETURN

-

+

SAVE

SETUP

EXIT

SYSTEM FREQUENCY

SELECT

1080/50i

Push F5(SAVE) Key!!

Time data display area

Function menu

Function buttons

Advertising