Since the indications cover various units, the corresponding parts listed below may not be present in some models.

(1) OPERATION lamp
(2) TIMER lamp

(3) LED CLEAN lamp

OPERATION

TIMER

LED CLEAN

ON/OFF

INDOOR UNIT

(1) Self-diagnostics Lamps

.... OFF

.... Blinking

.... ON (Illuminated)

LED Clean

(3)

Operation

(1)

Timer

(2)

Indication on indoor unit

(1) Sensor open circuit or short circuit

(2) Contact failure at connector or open circuit at terminal crimping location

(short-circuit detection only for the humidity sensor)

(3) Indoor/outdoor PCboard failure

(1) Sensor open circuit or short circuit

(2) Contact failure at connector or open circuit at terminal crimping location

(3) Outdoor PCboard failure

Outdoor PCboard failure

(1) Mis-wiring (2) AC power failure (3) Blown fuse (4) Power Relay failure

(5) Indoor or outdoor PCboard failure (6) Outdoor Fan Motor failure (7) Reactor failure

(8) High-Pressure Switch failure (9) Overload Relay failure (10) Magnetic Coil failure

* See detailed flowchart in this section.
(1) HIC or power Tr failure (2) Outdoor fan does not turn. (3) Instantaneous power outage

(4) Service valve not opened. (5) Outdoor fan blocked. (6) Continuous overload operation

(7) Compressor failure (8) Outdoor PCboard failure

(1) External ROM data failure (2) Outdoor PCboard failure
(1) Instantaneous power outage (2) HIC or power transistor failure

(3) Outdoor PCboard failure
(1) Outdoor PCboard failure (2) Outdoor power supply voltage failure

(1) Electric expansion valve failure (2) Capillaries choked (3) Shortage of refrigerant

(4) Continuous overload operation (5) Outdoor fan does not rotate (6) Outdoor PCboard failure

(1) Fan motor failure (2) Contact failure at connector (3) Indoor PCboard failure

(1) 4-way valve failure (heat pump model only)

(2) Outdoor PCboard failure
(1) Service valve not opened. (2) Shortage of refrigerant

(1) Open phase (2) Outdoor PCboard failure

(1) Fan motor failure (2) Contact failure at connector (3) Outdoor PCboard failure

(1) Mis-wiring (2) Blown fuse (3) Power Relay failure (4) Outdoor PCboard failure

(5) Compressor failure

* See detailed flowchart in this section.

(1) Indoor fan system failure (2) Shortage of refrigerant (3) Low-temperature operation

S01
S02
S03

S04

S05

S06
S07

E01

E02

E03
E04
E05
E06

E07

E08
E09
E10

E11

E12

E13

F10
F02
F13

F04/F12
F09/

F15 to F18

F08/

F21 to F24

F27

E05

P26

F31

P16
P07
P03

P01

P19
P15
P29
P22

E07/P04/P05

P20/P27

P11

Diagnosis Contents

Error

Code

Alarm

Code

Possible Malfunction

Room temperature sensor failure

Indoor heat exchanger sensor failure

Humidity sensor failure

Compressor temperature sensor failure

Outdoor heat exchanger sensor failure

Outdoor air temperature sensor failure

Outdoor electrical current detection

failure

Indoor/outdoor communications failure

(serial communications)

• HIC circuit failure

• Power Tr (transistor) circuit failure

• PAM circuit failure

• Active circuit failure

• 4-way valve switching failure

• Indoor zero-cross failure

• Outdoor system communications failure

• OLR operation

• Outdoor power supply open phase

• Outdoor coil freezing

Outdoor unit external ROM (OTP data)

failure
Peak current cut-off

Compressor discharge overheat

prevention activated.

No-refrigerant protection

DC compressor drive circuit failure

Outdoor fan operating failure

Freeze-prevention operation activated.

Indoor fan operating failure

37