4. How to Install the Outdoor Unit

First refer to Section 2. Installation Site Selection.

4-1. Wiring Instructions for the Outdoor Unit

Regulations on wire size differ from locality to locality. For

field wiring requirements, please refer to your local elec-

trical codes. Make sure that the installation fully complies

with all local and national regulations.

(1) Remove the 3 screws from the inspection panel.

(Fig. 46a)

Remove the inspection panel by sliding it downward

and pulling it toward you. (Fig. 46b)

(2) Connect the inter-unit and power supply line accord-

ing to the wiring system diagram on the inspection

panel. (Fig. 46c)

(3) When connections are completed, check that all

connections are correct as shown in the wiring sys-

tem diagram.

(4) Be sure to ground the unit according to your local

codes.

4-2. Routing the Tubing and Wiring

●

The tubing and wiring can be extended out in 3 direc-

tions: front, rear, and right. Use a nipper or similar

tool to cut out the knockout holes for the inter-unit

control wiring outlet, power wiring outlet, and tubing

outlet from the appropriate covers A and B. (Fig. 46d)

●

Route the tubing so that it does not contact the

compressor, panel, or other parts inside the unit.

Increased noise will result if the tubing contacts

these parts.

●

When routing the tubing, use a tube bender to

bend the tubes.

CAUTION

Terminal plate

Cabinet

Screw

Inspection panel

Fig.46a

Fig.46b

Fig.46c

Tubing outlet

Front

Right

Rear

Cover B

Cover A

Inter-unit

power line

Power supply line

(conduit)

Wiring outlet

Wiring outlet

(conduit)

Fig.46d