21

To unmount indoor unit

Press the 2

marks on the lower part of the indoor unit

and unlatch the tabs. Then lift the indoor unit and

unmount. (Fig. 42)

3-10. Frame Fastening Method

(1) Remove the screw cover on the bottom surface.

(Fig. 43)

(2) Fasten the frame to the rear panel using the 2 sup-

plied tapping screws 5/32" x 13/32" (4 x 10 mm).

(Fig. 43)

Under normal conditions, the installation design calls for

a less than 3/32" (2 mm) gap between the air conditioner

unit and the wall.

Confirm that the gap is appropriate (less than 2 mm).

3-11. Drain Hose

a)

The drain hose should be slanted downward to the

outdoors. (Fig. 44)

b)

Never form a trap in the course of the hose.

c)

If the drain hose will run in the room, insulate the

hose with insulation* so that chilled condensation
will not damage furniture or floors. (Fig. 45)

* Foamed polyethylene or its equivalent is recom-

mended.

NOTE

WARNING

Risk of Electric Shock

Do not supply power to the

unit or operate it until all

tubing and wiring to the out-

side unit are completed.

Condensation

Insulation material
(Locally purchased)
must be used.

Fig. 45

Screw

cover

Screw

Fig. 43

Push

Fig. 42

Slant

Drain
hose

Indoor
unit

Fig. 44

10-018 C3082-3682 2/15/10 11:50 AM Page 21