SanDisk CompactFlash Extreme III User Manual

Page 68

Advertising
background image

ATA Command Description

SanDisk CompactFlash Card OEM Product Manual

5.1.7

Idle Immediate–95H, E1H

This command causes the card to set BSY, enter the Idle (Read) mode, clear BSY and generate
an interrupt.

Table 5-14

Idle Immediate

Bit

7

6

5

4

3

2

1

0

Command (7)

E1H or 95H

C/D/H (6)

X

Drive

X

Cyl High (5)

X

Cyl Low (4)

X

Sec Num (3)

X

Sec Cnt (2)

X

Feature (1)

X

5.1.8

Initialize Drive Parameters–91H

This command enables the host to set the number of sectors per track and the number of heads
per cylinder. Only the Sector Count and the Card/Drive/Head registers are used by this
command.

NOTE

: SanDisk recommends not using this command in any system because

DOS determines the offset to the Boot Record based on the number
of heads and sectors per track. If a CompactFlash Memory Card is
"Formatted" with one head and sector per track value, the same card
will not operate correctly with DOS configured with another heads
and sectors per track value.

Table 5-15

Initialize Drive Parameters

Bit

7

6

5

4

3

2

1

0

Command (7)

91H

C/D/H (6)

X

0

X

Drive

Max. Head (no. of heads - 1)

Cyl High (5)

X

Cyl Low (4)

X

Sec Num (3)

X

Sec Cnt (2)

Number of Sectors

Feature (1)

X

02/07, Rev. 12.0

5-14

© 2007 SanDisk Corporation

Advertising
This manual is related to the following products: