SanDisk CompactFlash Card OEM Product Manual

ATA Command Description

Table 5-24 defines the valid extended error codes for the CompactFlash Memory Card Series
product. The extended error code is returned to the host in the Error Register. This command
must be the next command issued to the card following the command that returned an error.

Table 5-24

Extended Error Codes

Extended Error Code

Description

00h

No error detected

01h

Self test OK (no error)

09h

Miscellaneous error

20h

Invalid command

21h

Invalid address (requested head or sector invalid)

2Fh

Address overflow (address too large)

35h, 36h

Supply or generated voltage out of tolerance

11h

Uncorrectable ECC error

18h

Corrected ECC error

05h, 30-34h, 37h, 3Eh

Self test or diagnostic failed

10h, 14h

ID not found

3Ah

Spare sectors exhausted

1Fh

Data transfer error/aborted command

0Ch, 38h, 3Bh, 3Ch, 3Fh

Corrupted media format

03h

Write/erase failed

5.1.17

Seek–7XH

This command is effectively a NOP command to the card although it does perform a range
check of cylinder and head or LBA address and returns an error if the address is out of range.

Table 5-25

Seek

Bit

7

6

5

4

3

2

1

0

Command (7)

7XH

C/D/H (6)

1

LBA

1

Drive

Head (LBA 27-24)

Cyl High (5)

Cylinder High (LBA 23-16)

Cyl Low (4)

Cylinder Low (LBA 15-8)

Sec Num (3)

Sector Number (LBA 7-0)

Sec Cnt (2)

X

Feature (1)

X