4) Count up 10 place of code with <LINE> key and set with <FEED> key.

(With <LINE> key, +1 count up from 0 to f is displayed)




5) Cursor moves to 1 place after set.



6) Count up 1 place with <LINE> key and set with <FEED> key.



7) After setting STX, advance to ETX setting. Hereafter, each code is set

accordingly to the same procedures for STX setting.



8) Display returns to top of service mode, after setting.




*Code data for the time of factory is default

STX : 7 b h
ETX : 7 d h
ESC : 5 e h
ENQ : 4 0 h
CAN : 2 l h














CODE ADJ
STX : 7 B

CODE ADJ
STX : 7 B

CODE ADJ
STX : 7 B

CODE ADJ
ETX : 7 D

SERVICE
LVL SET

Chapter 8 - Operation Panel