SATO DR300 User Manual
Page 49

DR300 Operator Manual
47
Command
Printing Designation
Command images are as follows:
STX Initial
designation
ETX End
designation
COMMAND SPECIFICATION
1) Command summary
Command Detail Description
<A>
Designates start of data transmission.
<M>
d d
Designates information concerning the entire printing, such as paper
information, etc.
<L>
d d
Designates transmission of field parameter.
<D>
d d . .
Designates transmission of field data.
<Q>
d d d d Designates No. of labels to be issued.
<ID>
d d
Designates printing ID (Status-3 only).
<GM>
d d
Designates graphic data (BMP).
<T1H>
d d
Custom designed character registration (16x16).
<T2H>
d d
Custom designed character registration (24x24).
<Z>
Designates end of data transmission.
2) Initial Designation Command
STX <A> [02 H, 1B H, 41 H]
Command shows start of data transmission.
Communication error and transmitted data before reception of this command will be
ignored.
*For errors, like receiving uncontrollable symbol in case circuit on the host side is open/
closed, no error message will be displayed until error reception reaches 500 times.
3) End Designation Command
<Z>, ETX [1 BH, 5 AH, 03 H]
Command shows end of the data transmission.
Transmit media information, field information, print quantity, before transmitting this
command.
Chapter 9 - Online Programming