Appendix: Sample Configurations

A-5

Figure A-2. V-Switch 3000 Login Window

Enter the default user name, sanrad, and password, sanrad, and press
Enter on your keyboard. The CLI prompt > appears. You are now logged
in and ready to begin configuring your V-Switch for volume virtualization
and exposure.

STEP 6.

I

NITIALIZE

V-S

WITCH

From the open terminal emulation window, use the CLI command

init

to

name the V-Switch.

init –n VSwitch1

Use the CLI command

ip config set

to assign an IP address to the

network port Eth 1. Configure the port as active (1) to allow active
communications through the port.

ip config set –ip 172.17.200.174 –if eth1 –im
255.255.255.0 –act 1

STEP 7.

C

ONFIGURE I

SCSI

PORTAL

The port number you

set in the CLI must
coincide with the port

number you set in

your iSCSI initiator

configuration.

Use the CLI command

iscsi portal

create

to configure the iSCSI portal

on network port Eth 1 for iSCSI communications between the V-Switch and the
host station.

iscsi portal create –ip 172.17.200.174 –p 3260

Use the CLI command

iscsi portal show

to view the created iSCSI

portal.

iscsi portal show

Table A-2: iSCSI

Portal

Protocol

Address

Type

Address

Port

6

IPv4

172.17.200.174

3260