Appendix: Sample Configurations

A-31

STEP 14.

C

ONFIGURE

V-S

WITCH

2

I

SCSI

PORTALS

The port number you
set in the CLI must

coincide with the port

number you set in

your iSCSI initiator
configuration.

Use the CLI command

iscsi portal

create

to configure the iSCSI portal

on network port Eth 1 for iSCSI communications between the V-Switch and the
host stations.

iscsi portal create –ip 212.199.43.75 –p 5003

Use the CLI command again to configure the iSCSI portal for the inactive IP
address on Eth 1 to allow iSCSI communications via this IP on VSwitch2 in
the event of VSwitch1 failover.

iscsi portal create –ip 212.199.43.56 –p 5003

STEP 15.

C

HECK STORAGE DEVICES

Use the CLI command

storage show

to list the system-registered

storage devices on VSwitch1. This ensures that all disks were registered
during the disk auto-discovery scan. This also lists the default disk aliases
needed for creating your simple volumes.

storage show

Table A-10: Storage Disks as seen through V-Switch 1

Alias

Entity Name

LUN

Oper. Status Subdisk

Stor_1 2000002037f88fb8 0

Enabled entire

Stor_2 500507606058c90

0

Enabled entire

Stor_3 2000002037c32b1f 0

Enabled entire

Use the unique disk

entity names (WWUIs)

and NOT the default
disk aliases to

duplicate virtual

volume hierarchies in

each V-Switch.

Stor_4 2000002037c32450 0

Enabled entire

Use the CLI command

storage show

to list the system-registered

storage devices on VSwitch2. This ensures that all disks were registered
during the disk auto-discovery scan. This also lists the default disk aliases
needed for creating your simple volumes.

storage show

Table A-11: Storage Disks as seen through V-Switch 2

Alias

Entity Name

LUN

Oper. Status Subdisk

Stor_1 5005076006058c90 0

Enabled entire

Stor_2 2000002037f88fb8 0

Enabled entire

Stor_3 2000002037c32b1f 0

Enabled entire

Use the unique disk

entity names (WWUIs)
and NOT the default

disk aliases to

duplicate virtual

volume hierarchies in
each V-Switch.

Stor_4 2000002037c32450 0

Enabled entire