Chapter 6: Volume Configuration

6-5

The alias of Stor_1 is changed to Disk2JBOD5 for easier identification and it is
noted to save the disk for snapshots.

storage set –s Stor_1 –na Disk2JBOD5 –info save_for_snap
shots

The V-Switch supports write cache enabling for increased performance. Use
the CLI command storage disk set to enable or disable the write cache.

storage disk set

You need to define two parameters to change a device’s write cache setting:

S

WITCH

P

ARAMETER

D

EFINITION

S

TATUS

E

XAMPLE

-d

DISK

DISK DEVICE

MANDATORY

Disk2JBOD5

-wce

WRITE CACHE
ENABLED

WRITE CACHE
FUNCTION

MANDATORY

YES OR NO

yes

The V-Switch also recognizes all write-protected storage devices. Use the CLI
command storage details to view a device’s details, including if it is write-
protected.

storage details

You need to define one parameter to view a disk’s details:

S

WITCH

P

ARAMETER

D

EFINITION

S

TATUS

E

XAMPLE

-s

STORAGE

ALIAS OF STORAGE
TO VIEW

MANDATORY

Disk2JBOD5

Table 6-2: Storage

Details

Alias: Disk2JBOD5

Entity Name:

2000002037a9551e

LUN(Logical Unit Number)

0000000000000000

Vendor Name:

SEAGATE

Additional Info:

Transport type:

Fiber Channel

Oper. Status:

Enabled

Time since last Update:

8 days 3h:12m:16 sec 37
(1/60 Sec)

SCSI Version:

3