2. SELECTING THE INSTALLATION SITE

2-1. Indoor Unit

AVOID:

● areas where leakage of flammable gas may be expected.
● places where large amounts of oil mist exist.

● direct sunlight.
● locations near heat sources which may affect the

performance of the unit.

● locations where external air may enter the room directly.

This may cause “sweating” on the air discharge ports,

causing them to spray or drip.

● locations where the remote controller will be splashed with

water or affected by dampness or humidity.

● installing the remote controller behind curtains or furniture.
● locations where high-frequency emissions are generated.

DO:

● select an appropriate position from which every corner of

the room can be uniformly cooled.

● select a location where the ceiling is strong enough to

support the weight of the unit.

● select a location where tubing and drain pipe have the

shortest run to the outdoor unit.

● allow room for operation and maintenance as well as

unrestricted air flow around the unit.

● install the unit within the maximum elevation difference

above or below the outdoor unit and within a total tubing

length (L) from the outdoor unit as detailed in Table 1-8.

● allow room for mounting the remote controller about 3 ft.

off the floor, in an area that is not in direct sunlight nor in

the flow of cool air from the indoor unit.

Air delivery will be degraded if the distance from the floor to

the ceiling is greater than 10 ft.

NOTE

Concealed Duct (High-Static Pressure) Type
4-Way Air Discharge Semi-Concealed Type

3 ft.

3 ft.

3 ft.

3 ft.

3 ft.

Wall-Mounted Type

min.6 in.

Front View

min.
6 in.

min.
6 in.

Ceiling-Mounted Type

Side view

min. 10 in.

min. 2 ft.

Air intake

Air
discharge

min. 10 in.

Ceiling

Wall

Front view

Max. 10 in.

Obstacle

NOTE

The rear of the indoor unit can be installed flush
against the wall.

Fig. 2-1

Fig. 2-2

min. 2 in.

min. 2 in.

min. 3 ft.

Air
intake

Air

discharge

Obstacle

Ceiling

Wall

Wall

Side view

1-Way Air Discharge Semi-Concealed Type

Fig. 2-3

Fig. 2-4

19