6-4. Taping the Tubes

(1) At this time, the refrigerant tubes (and electrical wiring

if local codes permit) should be taped together with

armoring tape in 1 bundle. To prevent the condensation

from overflowing the drain pan, keep the drain hose

separate from the refrigerant tubing.

(2) Wrap the armoring tape from the bottom of the outdoor

unit to the top of the tubing where it enters the wall. As

you wrap the tubing, overlap half of each previous tape

turn.

(3) Clamp the tubing bundle to the wall, using 1 clamp

approx. each ft. (Fig. 6-10)

Do not wind the armoring tape too tightly since this will

decrease the heat insulation effect. Also ensure that the

condensation drain hose splits away from the bundle and

drips clear of the unit and the tubing.

6-5. Finishing the Installation

After finishing insulating and taping over the tubing, use

sealing putty to seal off the hole in the wall to prevent rain

and draft from entering. (Fig. 6-11)

NOTE

Insulated tubes Drain hose

Clamp

Tubing

Apply putty here