Table 3-4 – Sanyo R410A User Manual

Page 39

Advertising
background image

39

U

Fig. 3-61

Fig. 3-62

Indoor unit

Inspection
access

17-23/32

17-23/32

Air outlet duct flange

min.
9-27/32

mi

n

.

15-

3

/4

min. 25-19/32

22-27/

3

2

A (Suspension bolt pitch)

Electrical

component box

Refrigerant
tubing

mi

n

.

9-27/

32

Concealed Duct Type (U Type)

3-14. Required Minimum Space for

Installation and Service

This air conditioner is usually installed above the ceiling so that the
indoor unit and ducts are not visible. Only the air intake and air outlet
ports are visible from below.

The minimum space for installation and service is shown in
Fig. 3-61 and Table 3-3.

It is recommended that space is provided (17-23/32

× 17-23/32 in.)

for checking and servicing the electrical system.

Fig. 3-62 and Table 3-4 show the detailed dimensions of the indoor
unit.

Table 3-3

Type

A (Length)

Number of duct flanges

36

61-13/32 (1,560)

4

24

42-17/32 (1,080)

3

7, 12, 18

30-23/32 (780)

2

Dimension

Type

7, 12, 18

A

B

C

D

E

F

G

H

I

J

K

L

M

26-1/16

23-5/8

(7-7/8

Ч 3) 27-9/16 30-23/32 11-13/32 10-5/16 26-25/32 28-5/32

7-3/32

13-3/8

8

12

24

37-7/8

35-7/16

(7-3/32

Ч 5) 39-3/8 42-17/32 11-13/32 10-23/32 38-19/32 39-31/32

5-1/8

9-21/32

(9-21/32

Ч 1) 9-27/32

12

16

36

56-25/32

54-11/32

(9-1/16

Ч 6) 58-9/32 61-13/32 13-3/16 12-7/32 57-15/32 58-27/32

5-1/8

19-9/32

(9-21/32

Ч 2) 9-7/16

16

18

No. of holes

Refrigerant tubing joint (liquid tube)
Refrigerant tubing joint (gas tube)
Upper drain port (O.D. 1-1/4 in.)
Bottom drain port (O.D. 1-1/32 in.)
Suspension lug
Power supply outlet (2-ø1-3/16 hole)
Fresh air intake port (ø5-29/32 hole)
Flange for the flexible air outlet duct (ø7-7/8 hole)
Tube cover
Electrical component box
Flange for the air intake duct
(Option or field supply)

9

10

11

(Suspension bolt pitch)

(Suspension bolt pitch)

18-ø1/8

(Hole)

4-ø15/32

(Hole)

(Hole)

A (O.D.)

L-ø1/4

I

13/32

13/32

13/32

2-5/32

2-5/32

7-7/8

13/32

I

J

J

K

B

C
D

(5-29/32)

1-9/16

E

E

E

F

2-9/16

11-7/32

2-3/4

5-1/8

31/32

8-9/32

12-7/32

31/32

6-7/8

1-3/8

3-17/32

1-7/32

1-7/32

H (Duct suspension bolt pitch)

G (Ceiling opening dimension)

31/32

3-15/16

7-9/32

22-27/32

31/32

4-17/32

7-15/32

3-1

1/32

31/32

2-3/4

1-3/16

6-5/16

24-13/16

31/32

13/32

3-15/32

10-13/16

(Ceiling opening dimension)

10-1/4

(O.D.)

3/4

3/4

Inspection access

(17-23/32

17-23/32)

(Field supply)

Inspection access panel

Ceiling

2-15/16

Inter-unit control wiring

Unit: in.

Table 3-4

Unit: in. (mm)

Unit: in.

Unit: in.

07-007 W-2WAY_II_NA 1/23/07 6:09 PM Page 39