Chapter 6: setting configuration parameters, Factory default settings – Silex technology WLAN MODULE SX-550 User Manual
Page 39

silex
Page
33
Part Number 40183-101
Chapter 6:
Setting Configuration Parameters
The SX-550 module is equipped with a default configuration that works with most serial-to-Ethernet and
wireless connections. You can modify the settings to suit your installation requirements.
ExtendView is the recommended method for setting configuration parameters. However, regardless of the
method to access the configuration parameters, the method for modifying the parameters is virtually
identical.
Factory Default Settings
Table 19 displays the configuration parameter descriptions and settings with the default settings indicated
in a separate column.
Table 19 Factory Default Settings
Parameter Description
Settings
Default
Setting
Character
Bits per character
7, 8
8
Flow
Flow control
None, Xon, Xoff,
CTS/RTS
None
Parity
Parity
None, Even, Odd, Mark,
Space
None
Speed
Baud rate of bits per second
300, 600,1200, 2400,
3600, 4800, 7200,
9600, 14400,19200,
38400, 57600, 76800,
115200, 230400,
460800, 921600
9600
115200 – console
port default
Stop
Stop bits per character
1, 2
1
Mode
Line mode or serial port protocol
232, 422, 485, 485HD,
Disabled
232
Ecable
E-cable mode for TCP connections
Enable, Disable
Disable
Ecaddr
E-cable destination IP address
Set by user
N/A
Econn
E-cable connection attempt time
1-255 seconds
30 seconds